Windings failure and repair of shaded pole motor

Windings failure and repair of shaded pole motor


(1) Short circuit and wrong connection fault of salient pole motor stator main winding. The stator main winding of this kind of motor is multi-turn centralized winding made of high strength enameled round copper wire, and its short circuit fault is usually turned centralized winding, and its short circuit fault is usually inter-turn short circuit. After the short circuit between turns, the motor starts to reduce the torque, the starting current is large, the starting is difficult, the fuse is broken, the motor shell is overheating, and some other abnormal phenomena. The reasons are as follows:


A. The wire quality is poor, the winding method is improper, the drip drying is not complete, because the paint guide film is scratched or fallen off.

B. Improper use of the motor, often overloads operation.

C. The motor is overhauled and accidentally damaged the paint film due to magnetic damage.


(2) the elimination of the fault depends on the specific situation of the short circuit, the general method is:

First, use a multimeter or bridge to detect the resistance of several coils, the resistance value of small coils may be short circuit.


When a coil is judged to have a short circuit, it should be removed from the magnetic pole, stripped of the outer insulation belt, and carefully checked. If the short circuit between turns is in several layers on the surface, or only the paint film is scratched or fallen off, the insulation paper can be used to pack the insulation paper, and the insulating paint can be brushed and dried to repair the part. Finally, the outer insulation tape is wrapped, and the stator is dipped and dried.


(3) short circuit in the middle and inner layer, the number of turns is more, and the whole coil due to overheating and aging wire paint, should be replaced wire group.


(4) the winding wiring is wrong, generally, a few coil poles between the end and end of the wrong connection can cause the motor to start a difficult, unstable operation. Find out the wrong connection, correct it, only need to carefully check to local repair.