FailureReasonMeasures
The noise in reducer fastenersThe loose of fastenersTighten bolt/nut to the specified torque, replace damaged bolt/nut
Reducer's noise changesGear tooth gets damagedContact customers service department to check all the gear, replace damaged bolt/nut
Bearing clearance large gapContact customer service department, adjust bearing clearance
Broken bearingContact customer service department, replace damaged bearing
Too high working temperatureThe high oil level of the inside box bodyCheck oil surface height, adjust if necessary
Long-used oilContact customer service department, check the last time oil change, replace if necessary
Oil gets severely contaminatedContact the customer service department, change the oil
For reducer that equipped with lubricating oil cooling system, too low or too high coolant flow rateComprehensively regulate import and export of pipeline valves, check the free flow of water-cooling device
The too high temperature for coolantCheck temperature and adjust according to demand
Too low oil flow through water cooling device, reason: oil filter seriously blockedOil filter cleaning
Oil pump mechanical failureContact customer service department, check whether the function of the oil pump is normal or not, carry out the repair or change the oil pump if necessary
Reducer that is equipped with fan, fan cover's air inlet and/or body get seriously pollutedFan cover and housing cleaning
Reducer equipped with cooling spiral pipe: cooling spiral tube fouling insideContact customer service department, clean or replace the spiral pipe
Too high temperature in  bearingToo high or too low oil level in reducer boxCheck oil surface height at room temperature and refueling on-demand
Long-used oilContact customer service department, check last time oil change
Oil pump's mechanical failureContact customer service department, check whether the pump work normally or not, repair or change a new oil pump
Broken bearingContact customer service department, check the vibration measuring data, check and change the bearing according to the need
Bearing amplitude riseBroken bearingsContact customer service department, check the vibration measuring data, check and change the bearing according to the need
Damaged gearContact customer service department, check and change gear according to need
Non-return device temperature is too high, check function failureDamaged deviceContact customer service department, check and change non-return device according to need
Reducer leakageEnclosure cover or joint sealing adverseCheck seal and connection, if necessary, change a new seal
Radial shaft seal failurecontact customer service department, change the new radial sealing ring
Have water in oilHave sundry in oilCheck if water does exist in oil, and laboratory analysis.
Lube oil cooler or the cooling spiral pipe failureContact customer service department, find out leakage position, change water cooler.
Reducer machine ventilation when coming up with cool air and condensationUse the appropriate heat preservation material to guard the speed reducer, close air export, or change its direction on the structure
Pressure alarm monitoring device, equipped with a pressure lubrication device, lubricating oil-water cooling, and air cooling is the reducerOil pressure<0.5barsAt room temperature check the oil level height, according to the need to go check the oil filter, according to the need to change, contact the customer service department, check the normal functioning of the oil pump, oil pump repair or replace
Double switching filter indicator emits an alarmDouble switching filter cloggingAccording to the specification toggle switch filter will be blocked filter down and clean up
Oil supply system fault
See operating instructions on oil supply system description
The motor does not startPower interruptCheck to wire, when need correct
Fuse fusingReplace the fuse
The motor protection device has actionCheck motor protective device Settings are correct when need discharge failure
Motor contactor action, not in the control system failureCheck motor contactor control, when need troubleshooting
Motor not starting or starting difficultyThe motor should be a delta connection method, but it is a star connectionCorrect wiring way
Voltage or frequency gravely deviates from the rating when starting at leastTry to improve the power supply; Check the power cord section
The direction of rotation errorMotor wiring errorSwapping two-phase line
Rumble and current consumptionDamaged windingThe motor must send professional repair shop repair
Rotor windings touch
Fuse fusing or motor protective device immediately actionConductor short-circuitShort-circuit eliminate
Motor short circuitProfessional repair shop discharge failure
Connection wires errorCorrect connection mode
Electrical grounding short circuitProfessional repair shop discharge failure